The Dryer Vent Safety Council Podcast · DVSC
The Federal Disagreement Over Clothes Dryer Airflow examines why the U.S. Department of Energy deliberately restricts the exhaust of vented clothes dryers during standardized laboratory testing and how the AHAM Standard Simulator has been part of federal dryer testing since 1977. The episode follows an unusual technical trail involving the Standard Simulator, the Modified Exhaust Simulator, and three similar openings: 2 9/16 inches, 2 7/8 inches and 2 11/16 inches. Those fractions became consequential when field airflow research led utilities to ask DOE whether its laboratory exhaust condition should better represent residential dryer vent conditions. Most importantly, the episode explains the boundary between laboratory testing and field measurement. The AHAM simulator establishes a controlled exhaust restriction for repeatable testing. It does not establish a universal residential back pressure, airflow or equivalent dryer vent length. Understanding that distinction helps explain why the actual operating conditions of an installed dryer and dryer vent still matter. Dryer Vent Safety Council | Consistency Reduces Risk. For more information visit:http://www.dvsafe.org/
0:00SPEAKER_00How much difference can a few sixteenths of an inch really make?
0:04SPEAKER_00Two and nine sixteenths, two and seven eighths, and two and eleven sixteenths.
0:11SPEAKER_00Three openings separated by only a few sixteenths of an inch.
0:16SPEAKER_00Those fractions ended up at the center of a federal disagreement over how clothes dryers should be tested.
0:22SPEAKER_00Because when a vented dryer is tested under the U.S.
0:26SPEAKER_00Department of Energy procedure, it doesn't simply exhaust into an open room.
0:31SPEAKER_00Its exhaust is deliberately restricted, on purpose.
0:36SPEAKER_00And the device used to create that restriction has a name, the AHA Standard Simulator.
0:43SPEAKER_00Welcome to the Dryer Vent Safety Council podcast.
0:48SPEAKER_00AHAM is the Association of Home Appliance Manufacturers.
0:53SPEAKER_00It develops ANSI slash AHAM HLD one, the performance standard for household tumble type clothes dryers.
1:03SPEAKER_00Now HLD one is a performance testing standard.
1:08SPEAKER_00It isn't a dryer vent installation code, and it isn't a field diagnostic standard.
1:14SPEAKER_00Inside that standard, section three point three point five point one describes the standard simulator.
1:23SPEAKER_00The US Department of Energy, or DOE, incorporates that specific simulator into the federal closed dryer test procedure, and the language is crystal clear.