PE-Energy Industrial Supply – Powering Industry Excellence · PE-Energy
Appleton® EDS Factory Sealed Tumbler Switches give you explosionproof and dust-ignitionproof lighting/power disconnects rated for NEC/CEC Class I, Division 1 and 2, Groups B (select 1-gang units), C, D; Class II, Groups E, F, G; Class III; and NEMA 3, 7BCD, 9EFG, built for chemical plants, petrochemical plants, and refineries where every switch throw risks an ignition source. Here's how Appleton EDS factory sealed tumbler switches prevent arc ignition: arcing devices stay contained inside an explosionproof labyrinth switch (standard on most 20 Amp models) or inside a separate sealing chamber with prewired, factory sealed pigtail leads. All 20 Amp 4-way models and every 30 Amp model use that sealing chamber construction, no external sealing fittings required for installation. Smooth integral bushings protect conductor insulation, and every body has an internal ground screw plus stainless steel hex head cap screws for flame-tight assembly. Class I Division 1 Groups B C D tumbler switches are only the 1/2 inch and 3/4 inch 1-gang EDS units, shaded in the selection tables for Group B coverage alongside C and D. Factory assembled switch assemblies (EDKF/EDKR series), EFD mounting bodies, and blank bodies for brazed hubs are rated Groups C, D only, not B, so double-check your hazard classification before you spec a replacement part. Tandem bodies need external seals within 5 feet of each conduit entrance for Groups C and D. Running the EDS vs EDSC dead-end feed-thru decision: dead-end units like EDS150F1 (1/2 in. hub, 20A, 1-pole) terminate the run, while feed-thru units like EDSC150F1A continue it with an aluminum backbox and cover option. Hub sizes scale from 1/2 in. to 3/4 in. to 1 in. across 1-gang and 2-gang bodies, and configurations run 1-pole, 2-pole, 3-way, and 4-way in both front operated and rocker arm operated handles, lockable ON or OFF. 20 Amp models are rated 1 HP at 120 Vac/2 HP at 240 Vac; 30 Amp models (like EDS175F13 or EDS110R13) hit 2 HP at either voltage. For custom configurations, the Appleton EDS catalog number guide uses the EFD Cast Device Boxes symbol table: 0 blank, 1 for 1/2 in. threaded hub, 2 for 3/4 in., 3 for 1 in., with 1E/2E/3E for brazed union hubs, building strings like EFD-3NL-8-23203E. Appleton EFD mounting bodies brazed hubs ordering covers 1 through 5-gang malleable iron blank bodies (EFD1NL through EFD5NL) plus tandem bodies for custom hub layouts, just send us the sketch. See the full lineup: https://www.pe-energy.com/product/appleton-eds-factory-sealed-tumbler-switches/ Finish the install right with the NPBRKT nameplate mounting bracket installation torque spec: mount NPBRKTEFDB between the cover screws and cover (never in the ground joint flame path), torque cover screws to 35 in-lbs, and keep engraved text to 2 lines, 12 characters each. Standard finish is a triple coat of zinc electroplate, chromate, and epoxy powder; add suffix -A for copperfree aluminum bodies and covers. Send the catalog numbers...
0:00You know, in your facility flipping a light switch,
0:02it isn't really a mundane action. No, not at
0:06all. Right. It's essentially a localized microscopic
0:09detonation. And if you are the one listening
0:12to this right now and I am talking directly to
0:14you, the maintenance and reliability engineer
0:17managing a chemical plant or a petrochemical
0:19facility or a refinery, you already know the
0:23stakes here. Oh, absolutely. The stakes are.
0:25massive. Yeah, because when you're operating
0:27in atmospheres that are just saturated with ignitable
0:30vapors or combustible dusts, a simple unsealed
0:34toggle switch is literally the difference between
0:38a normal Tuesday and, well, a catastrophic facility
0:42leveling event. Yeah, the physics of the factory
More PE-Energy Industrial Supply – Powering Industry Excellence episodes →