Two Minnesota sprinkler fitters: FIELD, a beat-up old journeyman who's hung more pipe than you've walked past, and CODE, a cocky apprentice who's read the book twice and thinks that makes him dangerous. Raw, 18+ late-night talk on the MN Journeyman Sprinkler Fitter exam, built on the MSFC, NFPA 13, 14 and 25 and Minnesota rules, checked against the text, not barstool lore. Made by fitters who still work the job, for the brothers and sisters trying to get that card. Pair it with the MN Journeyman Exam Prep app. New episodes every day.
NFPA 13 Design Approaches: Pipe Schedule, Density/Area, Remote Areas & Room Design | MN Journeyman Exam Prep NFPA 13 design approaches: pipe schedule versus...
NFPA 13 In-Rack Sprinklers: Location, Spacing, Barriers & Design Criteria | MN Journeyman Exam Prep In-rack sprinklers in NFPA 13 Chapter 25:...
NFPA 13 CMSA Sprinklers: Installation, Spacing & Storage Applications | MN Journeyman Exam Prep Control mode specific application sprinklers: Chapter 13...
NFPA 13 Extended Coverage Sprinklers: Upright, Pendent & Sidewall Installation | MN Journeyman Exam Prep Extended coverage sprinklers in NFPA 13 Chapter 11:...
NFPA 13 Residential Sprinklers in NFPA 13 Systems: Listing, Spacing & Design | MN Journeyman Exam Prep Residential sprinklers used inside an NFPA 13 system:...
NFPA 13 Special Situations: Shafts, Stairways, Elevators, Vertical Openings & Stages | MN Journeyman Exam Prep NFPA 13 special situations: shafts, stairways,...
NFPA 13 Allowable Sprinkler Omissions: Concealed Spaces, Closets, Electrical Rooms, Canopies & Cloud Ceilings | MN Journeyman Exam Prep Allowable sprinkler...
Freeze protection for wet systems: the 40 degree rule, every allowed alternate (antifreeze or listed systems, insulation or casings holding 40 to 120, listed...
System acceptance: hydrostatic testing at 200 psi or 50 over working pressure for 2 hours, the dry-system 40 psi air test for 24 hours with 1.5 psi allowed...
NFPA 25 weekly and monthly inspections: the control valve ladder (sealed weekly, locked/supervised monthly), backflow and RPZ checks, dry and preaction valve...
ESFR installation: 100 sq ft maximum and 64 sq ft minimum per sprinkler, 12/10 ft spacing, 8 ft minimum, 30 ft ceiling and 25 ft storage limits, roof slope,...
Inspector's test connections, trip test manifolds, and pressure gauges. Wet-system test connection anywhere downstream with the smallest K-factor, dry-system...
Drainage: main drains, auxiliary drains, and pipe pitch. Half-inch and quarter-inch per 10 ft, everything half-inch in refrigerated areas, the drain sizing...
Control valves: listed indicating valves, PIVs and wall PIVs, check valves, and the four ways to supervise a valve. We cover valve location and...
The Hazen-Williams formula in plain English, the C-factor table (100, 120, 140, 150), why the fitting table is "C = 120 only" and how the multipliers work,...
Class I through IV, Group A/B/C plastics, cartoned vs. exposed, the 5/15 and 5/25/40 percentage rules, plastic pallets, open vs. closed arrays, rack types,...
Is there enough water, for long enough? At least one automatic supply, what counts as a supply, the 6-inch private main rule, pressure tanks, a live...
The plain-Jane system nobody studies. How an alarm check valve and retard chamber actually work (and why a plugged retard drain makes the outside bell ring...
Eighteen inches below the deflector splits the whole chapter. Above it, the spray pattern's still developing: the three times rule (24-inch cap, but not for...
Holding the pipe up, no sway bracing. Five times water-filled plus 250 lb vs. what the building has to carry, listed vs. unlisted parts, rod and U-hook...