Becker’s Healthcare -- Cardiology + Heart Surgery Podcast · Becker's Healthcare
In this episode, Curtiss T. Stinis, MD, FACC, FSCAI, Clinical Professor of Medicine, Director of Peripheral Interventions, Interventional Cardiology, Scripps Clinic, joins the Becker’s Healthcare Podcast to discuss the latest TAVR durability data, key differences between leading valve platforms, and what health system leaders need to understand about lifetime valve management. This episode is sponsored by Edwards Lifesciences.
Speaker 0: Hi, everyone. This is Lucas Voss with Becker's Healthcare. Thanks so much for tuning in to the Becker's Healthcare podcast series. It's great to have you. Today, we're talking to you about TAVR durability and strategic planning, what health system leaders need to know. Nobody better to have for this conversation. Doctor Curtis Stennis, he's the clinical professor of medicine, director of peripheral interventions and interventional cardiology at Scripps Clinic. Doctor Stennis, so great to have you on. Thanks for being here. Speaker 1: Thanks Thanks so much for having me, Lucas. Speaker 0: I wanna start off with introductions. I know I just mentioned your title, but I'd love to hear a little bit more about your work and your career. Speaker 1: Oh, yeah. Sure. Well, I'm a interventional cardiologist. I've been doing this now for, gosh, getting close to twenty years now. So I've been privileged to be involved with the TAVR space since its inception in The United States back in 2008 when we did the, you know, very first clinical trials back then. So been part of it since that time and fair amount of experience. Speaker 0: We'll touch on that here in a little bit. I wanna level set the conversation for our audience just a little bit. Right? Can you walk us through the most recent durability data for the two dominant TAVR platforms, and what platforms, and what does does that data tell us about where the landscape is right now? Speaker 1: Yeah. Sure. So the two dominant platforms in The United States are, of course, the balloon expandable Edwards Sapien valve and the self expanding, Medtronic Evolut valve. And, you know, when TAVR first started, you know, we were primarily focused on very high risk patients that didn't have other options like surgery. And, obviously, as time has gone on, we've, you know, done clinical trials on patients that are candidates for surgery, and so directly comparing these devices to surgery is is important. And, you know, long term, when we're treating younger and healthier patients, we have to think about how long will these devices last, And we really didn't have a lot of information about that until the last few years. But this year, we got some landmark data back. So, you know, these devices have been studied in various populations, including, you know, what are called intermediate risk surgical patients and low risk surgical patients. And within the last year, we've received data of on ten years' worth of the intermediate risk patients compared to surgery as well as seven years six and seven years, I should say, between these devices and surgery. To summarize, there's a big difference here in these in these devices. The self expanding platform, which uses porcine pericardium, doesn't seem to be as durable. Recently, the, Evolut low risk trial data was presented, which showed that right around five to six years, we start to see failures of the TAVR device. And by year seven, there's definitely significant, failure of these devices primarily due to aortic insufficiency, likely due to the material, the the leaflet tissue, sort of tearing and and, and falling apart. And those patients in that trial required, you know, more interventions either with redo, TAVR or with surgery. On the other hand, if you look at the balloon expandable valve data, specifically with the Edwards Sapien device, in the low risk patient population at seven years, there's no difference in, you know, a durability between the surgical arm and the TAVR arm. They're pretty much exactly identical. And that actually pans out with the intermediate risk patients at ten years as well, that TAVR durability at ten years for intermediate risk patients looks identical to surgery. So there's really a distinction or a difference between these devices. Speaker 0: Is that then a Teva class effect? And when you're looking at this data, almost again, like in some cases, a decade close to a decade of data now, what are some of the common myths the data then challenges? Speaker 1: Yeah. I think it's really important to realize that this is device specific durability data and not a judgment on TAVR as a therapy as a whole. You know, I've I've heard a lot of myths out there saying, well, you know, hey, TAVR doesn't work. It only lasts five or six six years, and here's the data to show that. And that's simply not true. That TAVR is not a class effect, that there's definitely differences in these devices. Similar to surgery, there have been some surgical valves that had early failure rates. And, you know, simply saying, well, surgery doesn't work based on that situation would be untrue. And I think it's really important to to distinguish the fact that these devices are distinctly different. Their their design is different. The tissue is different. And, clearly, we now know the durability is different. Speaker 0: And I wanna talk a little bit about more the of the the durability piece of this because I think that's it's very, very important. What does that data then, that durability data tell us about clinical outcomes and then also long term patient care? And certainly, you've just touched on it, that lifetime valve management piece. Speaker 1: Yeah. I think that's critical. And and as I mentioned earlier, if we're treating younger or healthier people, they're going to outlive these valves. We know that all bioprosthetic valves eventually will wear out or degenerate at some point in the patient's, you know, lifespan. So younger and healthier folks are going to end up needing a redo procedure of some type. What we can quote the what we can gather from the data from the Evolut low risk trial in particular is that around six and seven years when we see this increased failure rate due to aortic insufficiency, some of those patients were able to be treated with a new valve, a new TAVR valve, if you will, so called valve in valve. But sadly, many of them required surgery, to explant the TAVR valve. And what we know from the literature is that surgical explantation of TAVR valve is higher risk and more complex than standard surgical a v aortic valve replacement. In addition, importantly, that we can we can also see from the data is that many of these patients when the valve failed required an urgent or emergent and even salvage type procedure. About fifty percent of them required urgent, emergent, or salvage type procedures in total. And that puts a lot of burden on the health care system. Right? These are sicker people coming through the doors of the hospital requiring, you know, potentially more intensive care, longer days in the hospital, and a more complex and high risk intervention, whether it be a TAVR valve in valve or a surgical, you know, explantation and surgical, valve replacement. So these are sicker people requiring more resources from the health care, system, and ultimately, that's a more challenging subset of patients to deal with in health care. Speaker 0: I wanna talk a little bit more about this trickle down effect that you've just outlined very effectively because I think it's very important when we're looking at, again, the health system health care as a as a whole. How does valve durability then and and certainly the need for replacement too affect hospital quality, cost, and then also operational complexity? Speaker 1: Yeah. No. For sure. And, you know, as I mentioned earlier, valve design makes a difference not just in durability Yeah. But also in repeatability. So with the self expanding, Evolut platform, sort of claim to fame to that product is having a so called supraannular design, meaning the leaflets are sort of higher up in the frame to improve hemodynamics, with the intent of improving durability, which we now know is not directly linked. This improved hemodynamics or better hemodynamics by echo does not directly correlate with durability, certainly. But these valves can be harder to treat from a valve in valve perspective with a redo TAVR. And the reason for that is because those leaflets are higher in the frame, there's a higher likelihood of coronary obstruction. And this means that these procedures are more technically challenging and often require adjunctive therapies like leaflet modification, for example. And there are there are ways that the leaflets can be modified either with sort of home brew, methods of using various wires that we electrify and whatnot or a dedicated device known as the shortcut device, which is now, available by FDA approval in The US. But these these devices increase cost dramatically, increase the length of the procedure, which therefore increases cost, and, of course, because they're more complex, require additional adjunctive therapies like cerebral protection, longer hospital stays, etcetera. So that increases cost, burden to the health care system, for sure. Speaker 0: Doctor Stennis, it's so great to have you. One of the things that I've just gathered from your responses that that's something to keep in mind, the trickle down effect. It's very, very crucial, for leaders, to keep in mind both for cardiovascular leaders, but also health system executives. As we close our conversation, what are some of those key takeaways that you want cardiovascular leaders and certainly, again, those health system leaders, remind of and that what do they need to know and how should this data that we now have shape their thinking on valve selection and valve in valve planning? Speaker 1: Yeah. So, I mean, valve choice the first valve choice has absolute implications for lifetime management for these patients, and they're, therefore, also a direct implication for the health care systems that are going to be handling or taking care of these folks when that valve, you know, fails. Executives certainly don't choose valves, but they are responsible for outcomes and access and sustainability in their program. And so, you know, we have seen some facilities that have contracting issues or whatnot with certain valves, and that may limit options available to physicians at those institutions. And so I think executives should realize that TAVR is not a class effect, that there are differences in these devices, and that it's important to allow the physician to choose, you know, options which, you know, would may provide the best option or solution for that patient both now and in the future. I think it's it's you know, executive awareness is essential to support informed physician discussions, patient counseling, and long term care strategy. Speaker 0: Doctor Stennis, so great to have you. Thanks so much for spending some time with us. Speaker 1: Of course. My pleasure. Thanks for having me, Lucas. Speaker 0: And we also want to thank our podcast sponsor, Edwards Lifesciences. You can tune in to more podcasts from Becker's Healthcare by visiting our podcast page at beckershospitalreview.com.
More Becker’s Healthcare -- Cardiology + Heart Surgery Podcast episodes →