Anesthesia Patient Safety Podcast artwork

Anesthesia Patient Safety Podcast · Anesthesia Patient Safety Foundation

#324 Endotracheal Tubes Are Not All The Same

Your airway cart might look fully stocked, but one quiet change can reshape an entire intubation: a different endotracheal tube brand, a new material formulation, a redesigned cuff, or changes in diameter measurements. We take a close, practical look at endotracheal tube materials and design, and why supply chain instability and product discontinuations can turn a “routine” device into a patient safety risk, particularly for neonates, infants, and other pediatric patients where millimeters matter. We break down what actually varies between endotracheal tubes that share the same labeled size: PVC construction and the move away from DEHP, changes in flexibility, and how internal diameter, wall thickness, and manufacturing variability can increase resistance and impair ventilation. We also dig into cuffed endotracheal tubes and why there is no universal cuff standard. Cuff shape, cuff material, and contact surface area can change leak behavior, micro-aspiration risk, and the seal you rely on. Then we zoom in on failure points clinicians can miss, including pilot balloon and pilot line defects, the ability to pass a suction catheter in tiny cuffed tubes, distal tip designs that can deform, and when the presence or absence of a Murphy eye can matter in an emergency. To close, we read and reflect on a published statement responding to medication errors that harmed patients, reinforcing an essential distinction: a wrong drug or wrong route error is not the same thing as spinal anesthesia being unsafe. We highlight system safeguards that prevent neuraxial medication errors, including standardized labeling, separation of high-alert meds, and technology-assisted verification. Subscribe for more anesthesia patient safety deep dives, share this with a colleague who manages airways, and leave a review so more clinicians can find the show. What ET tube check has saved you from trouble? For show notes & transcript, visit our episode page at apsf.org: https://www.apsf.org/podcast/324-endotracheal-tubes-are-not-all-the-same/ © 2026, The Anesthesia Patient Safety Foundation

Sep 152026
14 minlength
115transcript lines
Publishertranscript source

Transcript first 15 of 115 lines

0:00AlliAre you standing near an anesthesia cart?

0:02AlliIf so, go ahead, open the drawer, and let's check out those endotracheal tubes.

0:07AlliWhat do you see?

0:08AlliAre you seeing the same endotracheal tubes that you're familiar with using, or something else, a different kind of endotracheal tube from a different manufacturer?

0:17AlliThis is the Anesthesia Patient Safety Podcast, and I'm your host, Ellie Bechtel.

0:22AlliWe've had a nice run of interview shows recently, but there are some new APSF newsletter articles that we need to check out.

0:29AlliSpoiler alert, we will be talking about endotracheal tubes on the show today.

0:34AlliBefore we dive further into the episode, we'd like to recognize Medtronic, a major corporate supporter of APSF.

0:42AlliMedtronic has generously provided unrestricted support to further our vision that no one shall be harmed by anesthesia care.

0:50AlliThank you, Medtronic.

0:52AlliWe wouldn't be able to do all that we do without you.

0:56AlliOur featured article is Endotracheal Tube Materials and Design: Navigating Airway Safety Amid Supply Chain Instability by Morgan Brown.

1:06AlliThis article was published online August 13th, 2026.

1:10AlliAnd to follow along with us, head over to apSF.org and click on the newsletter heading.

1:15AlliThe first one down is APSF Newsletter Articles, and then you can scroll down until you get to our featured article.

More Anesthesia Patient Safety Podcast episodes →